Get high performance without spending a fortune!
Ready for networking with XML output
The CARDIOVIT AT-102 has it all! The most important Cardiopulmonary Function Tests are combined in one single device:
Performance:
Operating Elements:
Resting ECG
Exercise ECG
10-sec. printout: A 10-sec. printout can be initiated at any time on the internal thermal printer
Spirometry
Option: Special trolley for mobile operation
The SCHILLER Thrombolysis Software (SCHILLER STP)is a software program designed to aid the physician’s decision-making process in the pre-hospital and emergency department setting by using medication, patient age, gender and ECG features to provide the predicted probability of acute cardiac ischemia or acute coronary syndrome (ACS). The SCHILLER STP software package enhances the computer-assisted ECG analysis capabilities as a software option in the CARDIOVIT AT-101 and CARDIOVIT AT-102 ECG recording devices.
Ripened Filter Technique withSSF SCHILLER Smoothing Filter,SBS SCHILLER Baseline Stabilizer andSPF SCHILLER Powerline FilterFeatures:
New innovative built-in communication module for the transmission of diagnostic recordings in XML formats over the standard Internet transfer protocol HTTP
Features:
Availability:
SPF SCHILLER Powerline Filter, SSF SCHILLER Smoothing Filter, SMF SCHILLER Myogram-Filter and SBS SCHILLER Baseline Stabilizer
SPF SCHILLER Powerline Frequency Filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by adaptive digital filtering.SPF can be activated in the following SCHILLER units: AT-1, AT-101, AT-101 easy, AT-101 Tele, AT-2 plus, AT-10 plus, AT-102, AT-104 PC, AT-110 and CS-200.
SSF SCHILLER Smoothing Filter, SMF SCHILLER Myogram Filter (muscle tremor filter): Adaptive low pass smoothing filter to suppress muscle tremor and high-frequency noise, without bothering the QRS complex.SSF is a unique Resting ECG filter, which can be activated in the following SCHILLER units: AT-101, AT-101 easy, AT-101 Tele, AT-2 plus, AT-10 plus, AT-102 and CS-200.SMF can be activated in the following SCHILLER units: AT-1, AT-101, AT-101 easy, AT-101 Tele, AT-2 plus, AT-10 plus, AT-102, AT-104 PC, AT-110 and CS-200.
SBS SCHILLER Baseline Stabilizer: Filter to suppress or greatly reduce base line fluctuations without changing the measurement values (for Resting and Exercise ECGs); safety standard: IEC/EN 60601-2-51 (protection against hazardous output).SBS is a unique Exercise ECG filter, which can be activated in the following SCHILLER units: AT-1, AT-101, AT-101 easy, AT-101 Tele, AT-2 plus, AT-10 plus, AT-102, AT-104 PC, AT-110 and CS-200.
All these filters do neither change the computerized ECG interpretation, the computerized ECG measurement value table nor the original QRS complexes.
They greatly help the user to have a valuable ECG right the first time.